PRODUCT INSTALLATION
eng 15
24 VOLT BATTERY CONNECTION
a - Power cable
b - 50 amp manual reset circuit breaker
c - Jumper wire (not supplied)
d - Common ground
1. Install a 50 amp manual reset circuit breaker in line with the
positive lead.
2. Connect the red battery lead from the power cable circuit
breaker to the positive (+) post on battery B.
3. Connect the black battery lead from the power cable to the
negative (–) post on battery A.
4. Connect the jumper wire (not supplied) between the negative
(–) post on battery B to the positive (+) post on battery A.
RED
BLK
a
b
c
d
37824
GRA
c
Battery A
Battery B